VeriSuite®

Patient Positioning and Verification


Used for tumor treatment in radiation therapy with photons, electrons or particles (protons)
1, VeriSuite® enables sub-millimeter precision in patient positioning. This high accuracy enables therapists to direct the dose precisely on the treatment target using the treatment device.2

World-Wide
+30

Treatment Rooms

Integrated Cone Beam CT Scans

Extra Feature

2D/3D &
3D/3D

Automatic Registration

ETR

Eye Treatment

Patient Positioning and Verification System

VeriSuite® 2D/3D Feature automatically aligns two DRR images rendered from a high quality CT scan of the patient with two corresponding X-ray images acquired during the treatment.
Thereby it provides six-degrees-of-freedom correction vector with a sub-millimeter accuracy. X-ray acquisition, automatic registration and correction calculations are completed within a few
seconds allowing for seamless integration in the treatment workflow.

VeriSuite® 3D/3D Feature automatically aligns a high-quality CT scan of the patient with an in-room acquired 3D volume, either from an In-Room CT scanner or from MedCom’s own Recotom® CBCT reconstruction algorithm. Thereby it provides three or six degrees of freedom correction vector with sub-millimeter accuracy.

VeriSuite® ETR combines acquisition of X-ray images for planning and patient position correction for eye treatment in one application.

VeriSuite® functionality includes image acquisition, interfacing with Oncology Information Systems (e.g. Mosaiq® or Aria), image registration, calculations for automatic correction of the patient’s position and sending the correction vector to the therapy control system. Additionally patient pre-positioning in a ‘Setup Room’ outside the treatment unit is supported.

Learn more about VeriSuite®

2D/3D IMAGE REGISTRATION
(XR↔DRR):

  • Automated single image or orthogonal image pair verification
  • Automated 3D verification for CBCT or in-room CT

  • Automated table correction calculation

3D/3D SCANS REGISTRATION
(CT↔CT/CBCT):

  • Any modality: planning CT and

      • CT-Series from In-Room-CT
      • Integrated Cone Beam CT scans
  • Automatic registration

  • Manual registration

  • Definition of region of interest

  • Manual annotations

ETR
Eye Treatment

  • Acquisition of X-ray images as planning basis including information about

      • The patient
      • The alignment hardware position
  • Overlay of planning contour images with acquired X-ray images for patient position correction.

VeriSuite® Treatment Room Support

Advanced Treatment Room Configurations:
Improving Radiographic Procedure Precision and Flexibility

  • Fixed Beam rooms

  • Inclined Beam rooms

  • Gantry Treatment room

  • Flexible and configurable for other room types

  • Up to three different radiographic axes simultaneously possible

Compatibility with Any DICOM Format

Advanced Treatment Room Configurations:
Improving Radiographic Procedure Precision and Flexibility

  • DICOM3, RT-Plan, RT-Structure etc

  • Interface to PACS via DICOM network

  • Import/Export RT Images

  • Import/Export CR Images

  • Import/Export DX Images

  • Data prefetching and local storage

  • 3D/3D offline review support for Mosaiq®

1 VeriSuite® is intended solely for patient positioning and verification in radiation therapy and must not be used for diagnostic purposes.
2 VeriSuite® is a medical device and must be operated by trained medical professionals only. For certification details see QA page